The family of UV VIS spectrophotometers from Analytik Jena AG covers the range from budget-priced single-beam photometers to high-performance double-beam spectrometers with Cooled Double Detection or Split Beam Technology and high-power diode-array systems. An extensive range of accessories for most diverse applications in biology, chemistry or physics is available including, for example, special cell holders for microcells, cylindrical cells, automatic cell changers, reflectance accessories, autosampler and sipper systems as well as a powerful Windows-based software package which provides maximum capabilities even in its standard configuration. With the optional additional packages of Kinetics, Bio, Film Thickness, Color and Multicomponent Analysis, the software meets all requirements and is indispensable to any laboratory.
Brochure
SPECORD Series
 
 
(Download 9,6 MB)
 
Product Guide
Molecular Spectroscopy
 
 
(Download 870 KB)
 
 

UV-VIS spectrophotometers

UV-ViS spectrophotometer SPEKOL 1300 / Low cost model

 

Спектрофотометр SPEKOL 1300
more o about SPEKOL 1300 ...

The SPEKOL 1300 UV VIS spectrophotometer is a single beam system from 190-1100 nm with an out-standing price – performance ratio.

Wavelength range: 190-1100 nm.
Spectral brandwidth: 4 nm

 

UV-ViS spectrophotometers SPECORD 30 and SPECORD 40

 
Спектрофотометр SPECORD 40

The SPECORD 40 UV VIS spectrophotometer operating in the range 190 - 1100 nm with DAB quality and the SPECORD 30® provide both scanning of spectra as well as fixed-wavelength measurements.
The robust SPECORD 30 single-beam spectrophotometer for the spectral region from near UV to near IR covers a wavelength range from 300 to 1100 nm.

SPECORD 40 is the high-performance spectrophotometer disposable for brewery analysis. With our special BEER ANALYTICS software modul for beer analysis, which has been developed by Analytik Jena in cooperation with the Facullty of Process Science of the Technical University Berlin, the specific Application of brewery analysis to comply with MEBAK and EBC are solved now.

Wavelength range: 300-1100 nm for SPECORD 30 and
190-1100 nm for SPECORD 40.
Spectral brandwidth: 3,4 nm for SPECORD 30 and
1,4 nm for SPECORD 40.

 

UV-ViS spectrophotometer SPECORD 50

 
Спектрофотометр SPECORD 50

The SPECORD 50 UV VIS spectrophotometer combines the high energy throughput of a single-beam photometer with the stability of a double-beam photometer.

The SPECORD 50 with the BEER ANALYTICS software module is a best spectrophotometer for brewering.

SPECORD 50 is the best high-performance spectrophotometer disposable for brewery analysis. With our special BEER ANALYTICS software modul for beer analysis, which has been developed by Analytik Jena in cooperation with the Facullty of Process Science of the Technical University Berlin, the specific Application of brewery analysis to comply with MEBAK and EBC are solved now.

Wavelength range: 190-1100 nm.
Spectral brandwidth: 1,4 nm

 

UV-ViS spectrophotometer SPECORD 200

 
Спектрофотометр SPECORD 200

SPECORD® 200 – powerful double-beam spectrophotometer
The innovative detector system – Cooled Double Detection – ensures exact real-time double-beam operation.

Wavelength range: 190-1100 nm.
Spectral brandwidth: 1,0 / 2,0 / 4,0 nm

 

UV-ViS spectrophotometer SPECORD 205

 
Спектрофотометр SPECORD 200

The double-beam systems of Analytik Jena's spectrophotometer family set new standards.
Fixed slit width.

Wavelength range: 190-1100 nm.
Spectral brandwidth: 1,4 nm

 

UV-ViS spectrophotometer SPECORD 210

 
Спектрофотометр SPECORD 210

The double-beam systems of Analytik Jena's spectrophotometer family set new standards.
Variable slit width.

Wavelength range: 190-1100 nm.
Spectral brandwidth: 0.5 / 1 / 2 / 4 nm

 

UV-ViS spectrophotometer SPECORD 250

 
Спектрофотометр SPECORD 250

New double-beam spectrophotometer with Cooled Double Detection system - ensures exact real-time double-beam operation.
Double Monochromator for reduced stray light (0.01 %T at 220 nm).
Passing all Pharmacopoeia demands.

Wavelength range: 190-1100 nm.
Spectral brandwidth: 0.5 / 1 / 2 / 4 nm

 

UV-ViS spectrophotometer SPECORD S600

 
Спектрофотометр SPECORD S600

Simultaneous High Performance UV VIS Spectrophotometer
SPECORD® S 600 – Precision and Speed in UV VIS Spectroscopy.
The new UV VIS Spectrophotometer SPECORD S 500 and
SPECORD S 600 combines the precision and convenient handling needed in laboratories with speed, reliability and superior optical performance.

Wavelength range: 190-1017 nm.
Spectral brandwidth: 1.6 nm

 

UV-ViS spectrophotometers SPECORD S 100 and SPECORD S 100 B

 
Спектрофотометр SPECORD S100

SPECORD® S 100,
a diode array spectrophotometer of the S class, provides reliable, fast and simultaneous high-precision and comfortable measurements.
The SPECORD® S 100 BIO – spectrometer of the S class – was developed for use in pharmaceutical and biological applications (for details, refer to bioanalytical solutions).

Wavelength range: 190-1020 nm.
Spectral brandwidth: 2.4 nm for SPECORD S 100 and
1,4 nm for SPECORD S 100 B.

 
Accessories

Accessories for SPECORD series

Accessories for SPECORD S100

 

TABLE OF TECHNICAL DATA FOR SPECORD SERIES

part 1

SPECORD 250

SPECORD 210

SPECORD 200

SPECORD S 100 /
S 100 BIO

Optical principle

Double-beam spectrophotometer with variable spectral resolution and CDD - Cooled Double Detection

Double-beam spectrophotometer with variable spectral resolution and CDD

Double-beam spectrophotometer with variable spectral resolution and CDD

Powerful diode array spectrophtometer for the UV to NIR range

Wavelength range

190 - 1100 nm

190 - 1100 nm

190 - 1100 nm

190 - 1020 nm

Photometric display

-8À ... 8À

-8À ... 8À

-8À ... 8À

-4À ... 4À

Photometric range

-4À ...4À (up to 900 nm)

-3À ...3À

-3À ...3À

-3À ...3À

Spectral bandwidth

variable 0,5 / 1 / 2 / 4 nm

variable 0,5 / 1 / 2 / 4 nm

variable 1 / 2 / 4 nm

2,4 nm for Specord S 100
1,4 nm for Specord S 100B

UV-Resolution (toluene-hexane)

≥ 2.1****

≥ 2.1****

≥2.1****

S 100 BIO ≥ 1,6

Wavelength accuracy (with holmium oxid filter)*

±0,5 nm

±0,5 nm

±0,5 nm

±1 nm

Wavelength reproducibility (with holmium oxid filter)*

±0,05 nm

±0,05 nm

±0,05 nm

±0,05 nm

Photometric accuracy

VIS at 546nm with Neutral glass filter hellma F4*

±0,005 A

±0,005 A

±0,005 A

±0,01 A

UV with Potassium dichromate according Ph.Eur.

±0,01 A

±0,01 A

±0,01 A

±0,015 A (S 100 BIO)

Stray light
200 nm (KCl Merck 1.08164.0001)
220 nm (NaI)
240 nm (NaI)
340 nm (NaNO2)



≤ 0,3% T

≤ 0,008% T
≤ 0,008% T
≤ 0,008% T



≤ 0,5% T

≤ 0,05% T
≤ 0,05% T
≤ 0,05% T



≤ 0,5% T

≤ 0,05% T
≤ 0,05% T
≤ 0,05% T



≤ 1% T
(S 100 BIO)
≤ 0,1% T

≤ 0,1% T

Basisline stability at 50 nm

≤ 0,00015 (RMS)

≤ 0,00015 (RMS)

≤ 0,00015 (RMS)

≤ 0,003 (RMS)

Longterm stability at 500 nm

±0,001

±0,001

±0,001

±0,002

Scanning speed

up to 6000 nm/min

up to 6000 nm/min

up to 6000 nm/min

up to 12 ms/spectra

part 2

SPECORD S 500/600

SPECORD 205

SPECORD 50

SPECORD 40

Optical principle

Powerful diode array spectrophtometer for the UV to NIR range

Double-beam spectrophotometer with fixed slit width

Double-beam spectrophotometer with SBT - Split Beam Technology

Single-beam spectrophotometer

Wavelength range

190 - 1020 nm***

190 - 1100 nm

190 - 1100 nm

190 - 1100 nm

Photometric display

-4À ... 4À

-8À ... 8À

-8À ... 8À

-8À ... 8À

Photometric range

-3À ...3À

-3À ...3À

-3À ...3À

-3À ...3À

Spectral bandwidth

1,6 nm

1,4 nm

1,4 nm

1,4 nm

UV-Resolution (toluene-hexane)

≥ 1,6

≥ 1,6

≥ 1,6

≥ 1,6

Wavelength accuracy (with holmium oxid filter)*

±0,5 nm

±0,5 nm

±0,5 nm

±0,5 nm

Wavelength reproducibility (with holmium oxid filter)*

±0,05 nm

±0,05 nm

±0,05 nm

±0,05 nm

Photometric accuracy

VIS at 546nm with Neutral glass filter hellma F4*

±0,0075 A

±0,0015 A

±0,01 A

±0,01 A

UV with Potassium dichromate according Ph.Eur.

±0,015 A

±0,01 A

±0,013 A

±0,014 A

Stray light
200 nm (KCl Merck 1.08164.0001)
220 nm (NaI)
240 nm (NaI)
340 nm (NaNO2)



≤ 0,5% T

≤ 0,1% T

≤ 0,1% T



≤ 0,5% T

≤ 0,05% T
≤ 0,05% T
≤ 0,05% T



≤ 1% T

≤ 0,05% T
≤ 0,05% T
≤ 0,05% T



≤ 1% T

≤ 0,05% T
≤ 0,05% T
≤ 0,05% T

Basisline stability at 50 nm

≤ 0,003
(RMS)

≤ 0,00015
(RMS)

≤ 0,003 (Peak to Peak)

≤ 0,003
(Peak to Peak)

Longterm stability at 500 nm

±0,002

±0,001

±0,001

±0,003

Scanning speed

up to 12 ms/spectra

up to 6000 nm/min

up to 6000 nm/min

up to 6000 nm/min

* Summary of the tolerances from the filters and spectrometers
** All data can checked witning validation of the instrument
*** ±2 nm
**** With slit 1 nm, 20 degree

}

 

lab equipment / analytical instruments
Analytik Jena AG autorized dealer

EVEREST, Ltd., 53-1,
(Moscow State University)
Leneinskie gori, Moscow 119234, Russia
phone / fax: +7 (095) 939-51-02,
938-29-85, 939-57-04
e-mail: info@everestlab.ru

.
.
.
.
.
.
.

 

Models, Models, Models! Free Modeling Portfolio! ModelCoast. Photographers! Free Photographic Portfolios. Imagegods. Visit The Best Free Image Hosting.